引用本文:[点击复制]
[点击复制]
【打印本页】 【在线阅读全文】【下载PDF全文】 查看/发表评论下载PDF阅读器关闭

←前一篇|后一篇→

过刊浏览    高级检索

本文已被:浏览 1490次   下载 1166 本文二维码信息
码上扫一扫!
制霉菌素搽剂微生物限度检查方法探讨
李毅1,王尊文1,姬俊2,刘琳1
0
(1.青岛市妇女儿童医院,山东青岛 266034;2.青岛市食品药品检验研究院,山东青岛 266071)
摘要:
目的:建立制霉菌素搽剂的微生物限度检查方法。方法:根据2015年版《中国药典》方法,采用平皿法、薄膜过滤法联合中和剂对制霉菌素搽剂进行微生物限度检查方法探讨。结果:利用预热至45℃的聚山梨酯-80 和卵磷脂的中和作用,制霉菌素搽剂需氧菌总数、霉菌和酵母菌总数采用薄膜过滤法联合中和剂的方法进行检查,控制菌的检查采用常规法,结果均符合2015年版《中国药典》的规定。结论:制霉菌素搽剂微生物限度计数方法综合采用薄膜过滤法、中和剂法(预热45℃)消除其对白色念珠菌的抗菌活性,使需氧菌、霉菌和酵母菌的回收结果符合药典要求。按2015年版《中国药典》方法对控制菌进行实验,控制菌检查可采用常规法进行。
关键词:  制霉菌素搽剂  方法适用性试验  微生物限度检查  薄膜过滤法
DOI:doi:10.13407/j.cnki.jpp.1672-108X.2018.11.016
基金项目:
Discussion on Microbial Limit Test of Nystatin Liniment
Li Yi1 , Wang Zunwen1 , Ji Jun2 , Liu Lin1
(1.Qingdao Women and Children's Hospital, Shandong Qingdao 266034, China;2.Qingdao Institute for Food and Drug Control, Shandong Qingdao 266071, China)
Abstract:
Objective: To establish a method for microbial limit test of nystatin liniment. Methods: According to the Chinese Pharmacopoeia (2015 Edition), the plate count method, membrane-filter method combined with neutralizing agent were adopted to conduct the microbial limit test on nystatin liniment. Results: The neutralization of polysorbate-80 and lecithin preheated at 45℃ were used, the total aerobic bacteria, mold and yeast of the nystatin liniment were examined by membrane-filter procedure combined with a neutralizer, the controlled bacteria were examined by conventional methods. All results of examinations were in line with the specifications of the Chinese Pharmacopoeia (2015 Edition). Conclusion: The microbial limit counting method of nystatin tincture has combined membrane-filtration method with neutralizer method (with preheating at 45℃) to eliminate the antibacterial activity against Candida albicans, so that the recovery results of aerobic bacteria, mold and yeast can meet the specifications of pharmacopoeia. According to the Chinese Pharmacopoeia (2015 Edition), the control bacteria can be examined by conventional methods.
Key words:  nystatin liniment  employment and suitability test  microbial limit test  membrane-filter procedure

用微信扫一扫

用微信扫一扫